New Generation

Heavy Duty Axial Roof Unit

Excl. VAT

  • Robust, heavy duty construction.
  • New Generation downflow supply air units can also be supplied.
  • Adjustable pitch impellers provide performances to suit a wide range of applications.
  • Impellers can be GRP, aluminium, nylon or anti-static to suit the application, GRP is standard.
  • Shutters are a standard component for the RVE and RSS models and are an optional extra for the RDE units.
  • Can be mounted at angles up to 30°.
  • All standard motors are speed-controllable using variable speed drives.
  • Can be used for free intake and ducted applications.
  • Multi-speed motors, as well as motors to meet Ex d, Ex e, Ex nA and Ex tD standards can be supplied.

SKU: EFAP-38

Quantity

Got a question about this product?

Email us or call us on +603 7846 0340 (Malaysia)
or +91 33-24988126 (India)

Compatible Accessories

Overview

The heavy duty New Generation Series of axial roof units has been designed for a wide range of free intake and ducted applications. These exhaust fans are suitable for a wide range of commercial and industrial applications for handling clean air through to smoke-spill. There are 9 sizes in the series extending from 315 to 1250mm diameter.

Features and Benefits

Smoke-Spill Application

The New Generation RSS Series of smoke-spill fans has been fully tested to meet the air performance and high temperature requirements of Standards AS/NZS1668.1:1998 and AS4429:1999.

Discharge Damper Fail-open Latching

An additional requirement of AS/NZS1668.1:1998 with respect to un-sprinklered buildings (300°C for 30mins) requires dampers to fail-open during smoke spill operation. The fail-open discharge damper latches come in two forms; the first being a manual release type requiring manual closing after the fan has been run. The second design, an electro-mechanical type permits the shutter latch to release and close automatically after the fan stops. For advice on smoke-spill wiring requirements refer to AS/ NZS1668.1:1998.

Weather Resistance

Mushroom cowls limit water ingress in a range of weather conditions.

Protection

Thermistors can be provided on all motors except when standards specifically exclude their use.

Testing

All units tested to BS848:Part 1, 1980 (airside performance) and BS848:Part 2, 1985 (sound performance).

Additional Information

Accurate selections, including comprehensive Noise Data, can be obtained from your local Elta Fans office or from our Product Selection Program. Refer to Elta Fans for performances at speeds other than shown. When shutters are fitted ensure the roof unit is mounted with the shutter spindle pointing down the roof. When shutters are fitted to the RDE models derate the performance by 15-20%. Where prevailing winds are high we recommend the fitting of Magloks®. For capacities greater than shown for the New Generation Series refer to the HC and SS series.

Specification

Construction

Galvanised steel bases; cowls/wind bands are of plastic, fibreglass or galvanised steel. The RVE and RSS models are all steel construction. Impeller blades can be GRP, aluminium, nylon or anti-static to suit the application. GRP is standard.

Motor

The fans are built with squirrel cage induction motors with sealed for life ball bearings. Motors to suit a wide range of voltages and frequencies can be supplied. Motors with 2-speed windings, or to meet Ex d, Ex e, Ex nA and Ex tD Standards, can be supplied. When fans are required for non-standard air applications this must be nominated at the time of enquiry.

Control

Speed controllable using variable speed drives.

Typical Applications

Libraries and Archives
Libraries and Archives
Hospitals and Hospices
Hospitals and Hospices
Laboratories
Laboratories
Dental Surgeries
Dental Surgeries
Veterinary Clinics
Veterinary Clinics
Mortuaries
Mortuaries
Care and Nursing Homes
Care and Nursing Homes
Operating and Mobile Theatres
Operating and Mobile Theatres
Pharmacies
Pharmacies
Schools
Schools
Colleges and Universities
Colleges and Universities
Nurseries
Nurseries
Mobile Classrooms
Mobile Classrooms
Student Accommodation
Student Accommodation
Dark Rooms
Dark Rooms
Canteens and Food Courts
Canteens and Food Courts
Fast Food Outlets
Fast Food Outlets
Commercial Kitchens
Commercial Kitchens
Restaurants and Bars
Restaurants and Bars
Fire and Police Stations
Fire and Police Stations
Law Courts
Law Courts
Places of Worship
Places of Worship
Government Buildings
Government Buildings
Prisons and Detention Centres
Prisons and Detention Centres
Town Halls and Community Centres
Town Halls and Community Centres
Airport Terminals
Airport Terminals
Train and Bus Stations
Train and Bus Stations
Theatres
Theatres
Gyms
Gyms
Sports Centres
Sports Centres
Swimming Pools
Swimming Pools
Stadiums and Arenas
Stadiums and Arenas
Cinemas
Cinemas
Bowling Alleys
Bowling Alleys
Ice Rinks
Ice Rinks
Go Karting Tracks
Go Karting Tracks
Indoor Play Centres
Indoor Play Centres
Theme Parks
Theme Parks
Spas
Spas
Museums and Galleries
Museums and Galleries
Supermarkets
Supermarkets
Shopping Centres
Shopping Centres
Departmental Stores
Departmental Stores
Banks
Banks
Laundrettes and Dry Cleaners
Laundrettes and Dry Cleaners
Petrol Stations
Petrol Stations
Car Showrooms
Car Showrooms
Nail and Beauty Salons
Nail and Beauty Salons
Call Centres
Call Centres
Portable and Temporary Offices
Portable and Temporary Offices
Telecoms Buildings
Telecoms Buildings
Office Buildings
Office Buildings
TV and Recording Studios
TV and Recording Studios

Customers Also Viewed

ABD – Butterfly Shutters

ABD – Butterfly Shutters

CTRL-M Speed Controller with On/Off Switch

CTRL-M Speed Controller with On/Off Switch

EC Controller – Pressure Controller
EC

EC Controller – Pressure Controller

EC Sensors – Combined Humidity And Temperature Sensor
EC

EC Sensors – Combined Humidity And Temperature Sensor